Cerere oferta

    Tastează codul: captcha

      Descarcă catalogul TopMetrology

      Tastează codul din dreapta in câmpul de jos: captcha

      Difractometru cu raze X pentru determinarea austenitului retinut - GNR AreX

      Complete automated instrument to determine Retained Austenite

      GNR is proud to offer a unique and outstanding instrument able to measure in an automated and easy to use way Retained Austenite in compliance with ASTM E 975 -03.

      Accurate  measurement of the retained austenite levels is important in the development and control of heat treatment process in steel industry.

      X-Ray Diffraction (XRD) is considered the most accurate method available that can accurately determine retained austenite levels down to 0.5%.

      The integrated intensities of the austenite (220) and (311), and the ferrite (200) and (211) diffraction peaks are measured on the AREX diffractometer. The use of multiple diffraction peaks minimizes the effects of preferred orientation and allows interference from carbides to be detected.

      ARE X is a fixed angular range X-Ray Diffractometer equipped with the most modern technical features which grant accuracy, precision, safety and easiness of use, especially designed for quantitative determination of Retained Austenite.

      ARE X is the unique instrument able to guarantee compliancy with the ASTM E 975 – 03.

      Thanks to ARE X innovative concept, Retained Austenite volume percentage can be measured in few minutes, just placing the sample and pressing start button.

      Applications:

      Quantitative determination of retained austenite content in heat-treated steels by x-ray diffraction has provided a reliable mean of controlling properties and ensuring quality.

      X-Ray Diffraction is considered the most accurate method of determining the amount of retained austenite in steels.

      Using „ASTM E 975-03 Standard Practice for X-ray Determination of Retained Austenite inSteel with Near Random Crystallographic Orientation“ along with the ARE X, retained austenite issues can be easily monitored and controlled.

      X Ray Generator Maximum Output Power 3 kW
      Output Stability < 0.01 % (for 10% power supply fluctuation)
      Max Output Voltage 60 kV
      Max Output Current 60 mA (option: 80 mA)
      Voltage Step Width 0.1 kV
      Current Step Width 0.1 mA
      Ripple 0.03% rms < 1kHz, 0.75% rms > 1kHz
      Preheat and Ramp Automatic preheat and ramp control circuit
      Input Voltage 230 Vac +/-10%, 50 or 60 Hz, single phase
      X-Ray Tube Type Glass Mo anode (option: Ceramic Mo anode),
      Focus 0.4 x 8 mm FF
      Collimation Monocapillary collimator: diameter 1-2 mm
      Max Output 3.0 kW
      Goniometer Configurations Vertical geometry
      Angular Range 27° < 2 theta < 40°
      Angular accuracy +/- 0.001°
      Sample Holder Dimensions 110 mm x 150 mm
      Detector Type Microstrip solid state
      Case Dimensions Width 658 mm, heigh 1059 mm, depth 762 mm
      Leakage X-rays < 1 mSv/Year (full safety shielding according to the international guidelines)
      Processing Unit Computer Type Personal Computer, the latest version
      Items controlled X-ray generator, detector, counting chain
      Basic Data Processing

      Creation of calibration curves. Retained Austenite quantification

      Software

      Acquisition and Analytical SW: Austenite

      Written for Windows 7 is the program designed for the control of the AREX Diffracto­metric System.

      Automatic Retained Austenite quantification conform to ASTM E 975-03 Standard Practice.

      Display, printout and disk storage of results.

      Описание

      Complete automated instrument to determine Retained Austenite

      GNR is proud to offer a unique and outstanding instrument able to measure in an automated and easy to use way Retained Austenite in compliance with ASTM E 975 -03.

      Accurate  measurement of the retained austenite levels is important in the development and control of heat treatment process in steel industry.

      X-Ray Diffraction (XRD) is considered the most accurate method available that can accurately determine retained austenite levels down to 0.5%.

      The integrated intensities of the austenite (220) and (311), and the ferrite (200) and (211) diffraction peaks are measured on the AREX diffractometer. The use of multiple diffraction peaks minimizes the effects of preferred orientation and allows interference from carbides to be detected.

      ARE X is a fixed angular range X-Ray Diffractometer equipped with the most modern technical features which grant accuracy, precision, safety and easiness of use, especially designed for quantitative determination of Retained Austenite.

      ARE X is the unique instrument able to guarantee compliancy with the ASTM E 975 – 03.

      Thanks to ARE X innovative concept, Retained Austenite volume percentage can be measured in few minutes, just placing the sample and pressing start button.

      Applications:

      Quantitative determination of retained austenite content in heat-treated steels by x-ray diffraction has provided a reliable mean of controlling properties and ensuring quality.

      X-Ray Diffraction is considered the most accurate method of determining the amount of retained austenite in steels.

      Using „ASTM E 975-03 Standard Practice for X-ray Determination of Retained Austenite inSteel with Near Random Crystallographic Orientation“ along with the ARE X, retained austenite issues can be easily monitored and controlled.

      X Ray Generator Maximum Output Power 3 kW
      Output Stability < 0.01 % (for 10% power supply fluctuation)
      Max Output Voltage 60 kV
      Max Output Current 60 mA (option: 80 mA)
      Voltage Step Width 0.1 kV
      Current Step Width 0.1 mA
      Ripple 0.03% rms < 1kHz, 0.75% rms > 1kHz
      Preheat and Ramp Automatic preheat and ramp control circuit
      Input Voltage 230 Vac +/-10%, 50 or 60 Hz, single phase
      X-Ray Tube Type Glass Mo anode (option: Ceramic Mo anode),
      Focus 0.4 x 8 mm FF
      Collimation Monocapillary collimator: diameter 1-2 mm
      Max Output 3.0 kW
      Goniometer Configurations Vertical geometry
      Angular Range 27° < 2 theta < 40°
      Angular accuracy +/- 0.001°
      Sample Holder Dimensions 110 mm x 150 mm
      Detector Type Microstrip solid state
      Case Dimensions Width 658 mm, heigh 1059 mm, depth 762 mm
      Leakage X-rays < 1 mSv/Year (full safety shielding according to the international guidelines)
      Processing Unit Computer Type Personal Computer, the latest version
      Items controlled X-ray generator, detector, counting chain
      Basic Data Processing

      Creation of calibration curves. Retained Austenite quantification

      Software

      Acquisition and Analytical SW: Austenite

      Written for Windows 7 is the program designed for the control of the AREX Diffracto­metric System.

      Automatic Retained Austenite quantification conform to ASTM E 975-03 Standard Practice.

      Display, printout and disk storage of results.

      Виж повече Вижте по-малко

      Имате ли още въпроси?

      You can request an offer

      Difractometru cu raze X pentru determinarea austenitului retinut - GNR AreX

      Request offer

      Финансиране

      Финансови решения за закупуване на ново оборудване, чрез BCR Leasing или Grenke.

      Вижте Методи за финансиране

      Вижте продуктовия каталог

      Можете да намерите всички наши продукти, на които винаги можете да разчитате!

      Отворете каталога
      This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.